# RWC Projection Packet with factors from Brian Timin: RWC growth calcs v5.xlsx
# National projection factors based on Frost and Sullivan report from Gil Wood at OID:
#  Projected wood heater NSPS emissions 12-15-11.docx
# 2104008100 (Fireplaces: general): Number of 2008 appliances and growth rates from Frost & Sullivan,
#   adjusted to account for US/Canada split (*0.87).  Also adjusted to account for 42% of people who
#   never use their woodburning fireplace (*0.58)
# x220,x230,x320,x330 (Wood stoves: inserts & freestanding EPA certified, non and catalytic):
#   Number of 2008 appliances and growth rates from Frost & Sullivan, adjusted to account for US/Canada
#   split (*0.87).  Existing units plus projected new units.  Assumes no removal of existing units.
# x210,x310 (Conventional non-certified woodstoves and inserts): Existing units, assumes no new conventional
#   stoves.  Assumes 10% of all new certified woodstoves, inserts, and pellets stoves will replace existing
#   conventional stoves.
# 2104008400 (pellet stoves): Number of 2008 appliances and growth rates from Frost & Sullivan, adjusted to
#   account for US/Canada split (*0.87).  Existing units plus projected new units.  Assumes no removal of existing units.
# 2104008510 (Furnace: indoor, cordwood): Number of 2008 appliances from industry source and growth rates from
#   Frost & Sullivan, adjusted to account for US/Canada split (*0.87).  Existing units plus projected new units.
#   Assumes all existing units (197,362) will be replaced by new units by 2020.  This allows for new growth in
#   addition to existing units being taken out of the system.
# 2104008610 (Outdoor hydronic heaters): Number of 2008 appliances and growth rates from Frost & Sullivan,
#   adjusted to account for US/Canada split (*0.87).  Existing units plus projected new units.
#   Assumes 10% of new outdoor heaters will replace existing heaters.
# NEW YORK:  Used RPO emissions which inccrrectly assigned OHH to fire pits (2104008700), therefore we
#   assigned the OHH factor to NY only.
#   Also lumped all woodstoves into 1 SCC (2104008320), therefoore we created a composite NY-specific
#   projection factor for this SCC that is a weighting of NEI (all woodstove SCCs) projections
# For more specifics see workbook: RWC_PF_2020_PMNAAQS.xlsx
# THIS PACKET EXPORTED FROM: /garnet/home/rhc/2007v5/mk_PP_RWC_2020only.sas
,2104008100,1.088110113,,,,"! Fireplace: general"
,2104008210,0.95,,,,"! Woodstove: fireplace inserts; non-EPA certified"
,2104008220,1.46201133,,,,"! Woodstove: fireplace inserts; EPA certified; non-catalytic"
,2104008230,1.46201133,,,,"! Woodstove: fireplace inserts; EPA certified; catalytic"
,2104008310,0.953018482,,,,"! Woodstove: freestanding, non-EPA certified"
,2104008320,1.46201133,,,,"! Woodstove: freestanding, EPA certified, non-catalytic"
,2104008330,1.46201133,,,,"! Woodstove: freestanding, EPA certified, catalytic"
,2104008400,2.271864957,,,,"! Woodstove: pellet-fired, general (freestanding or FP insert)"
,2104008510,1.716307272,,,,"! Furnace: Indoor, cordwood-fired, non-EPA certified"
,2104008610,1.563333301,,,,"! Hydronic heater: outdoor"
36000,2104008320,1.152634865,,,,"! NY all woodstoves including indoor furnaces, composite PF based on NEI emissions at wood stoves"
36000,2104008700,1.563333301,,,,"! NY incorrect SCC assignment, really Outdoor Hydronic Heaters, so PF is from OHH"